(512) 396-2376 ext. 129 Estimating@heldenfels.com
Stacks of rectangular concrete slabs with multiple circular holes are arranged on a dusty construction site under a blue sky with scattered clouds. Trees and buildings are visible in the distant background.
A blue shield icon with a white check mark in the center, symbolizing security, protection, or verification.
Superior Quality Control
A blue outline illustration of a stopwatch showing the time at approximately 4:22.
Fast Installation
Blue letters
100+ year Lifespan

Duct Bank

Heldenfels Enterprises precast duct banks provide a durable, efficient solution for housing and protecting underground electrical and communication conduits in industrial, commercial, and utility applications.

Manufactured in a controlled plant environment, these precast systems deliver consistent conduit alignment, proper concrete cover, and reliable spacing—helping reduce installation time and minimize on-site labor compared to field-built duct banks.

Precast duct banks can be configured in a wide range of conduit layouts, from smaller runs supporting light service to large, high-density banks designed for heavy electrical loads and future expansion. Built to project specifications and delivered ready to install, Heldenfels Enterprises duct banks support safer construction practices, improved schedule certainty, and long-term performance for critical underground infrastructure.

Product Information
Technical Specs
Configuration (H × W) # of Conduits (max) Typical Use / Notes
1H × 2W 2 conduits Light service runs, small circuits, minimal conduit requirement
1H × 3W 3 conduits Modest electrical service, small installations
1H × 4W 4 conduits Small-to-medium service, extra conduit capacity for future growth
1H × 5W 5 conduits Service with some growth allowance, redundant conduit, small systems with future expansion in mind
2H × 2W 4 conduits Medium capacity runs where vertical stacking helps reduce trench width
2H × 3W 6 conduits Medium service / power feeder bank, often used where a single row isn’t enough
2H × 4W 8 conduits Larger service runs, feeder circuits, more capacity for growth or redundancy
2H × 5W 10 conduits Heavier electrical needs, possibly multiple feeders or mixed services
3H × 2W 6 conduits Compact vertical stacks — useful when trench width is limited but depth allows stacking.
3H × 3W 9 conduits Common “medium-large” duct bank for campus / facility power distribution.
3H × 4W 12 conduits Larger feeder banks, industrial/commercial distribution, reserved spare conduits.
3H × 5W 15 conduits Heavy-duty runs — good for large facilities or future-proofing.
4H × 2W 8 conduits Deep vertical stack — useful when space is very limited horizontally.
4H × 3W 12 conduits Large installations where trench width is constrained but depth is available.
4H × 4W 16 conduits Substantial conduit bank — heavy service/feeder infrastructure.
4H × 5W 20 conduits Very large installations: data centers, large industrial facilities, campus-scale electrical distribution.
5H × 2W 10 conduits Deep stack for heavy capacity where trench width is limited.
5H × 3W 15 conduits High-capacity central duct bank for major infrastructure.
5H × 4W 20 conduits High-density conduit bank, good for future expansion, redundancy.
5H × 5W 25 conduits Maximum typical capacity per single 116″ precast section (standard manufacturer max) — used for large scale installations.
Delivery & Installation
On average, box beams take about 6-8 weeks before they are ready to leave our facility. Our delivery network makes shipping fast and easy! Each project is different and your timeline will be discussed when the order is placed.
Applications & Use Cases

Precast box beams are used in highway and roadway bridges, pedestrian crossings, parking structures, and marine platforms, providing efficient, high-strength solutions for short- to medium-span structures that demand durability and rapid installation.

Notes / Caveats
  • These numbers assume use of standard conduit sizes (4″ or 6″) as in common precast systems.
  • The “height × width” refers to how conduits are stacked in the cross-section, not physical dimensions — actual outside dimensions depend on conduit outer diameter, spacing between conduits, and concrete cover/encasement.
  • Many precast sections are built to a standard length (for example, 116 inches ~ 9.6 ft) for modularity.
  • For large conduit banks (many conduits), it’s common to “stack or side-by-side” these standard sections to build up the needed capacity or geometry.
Product Information
Technical Specs
Sizes: Built to Specifications
Thickness: Built to Specifications
Height Options: Built to Specifications
Installation: Crane ready with lifting hardware
Delivery & Installation
On average, box beams take about 6-8 weeks before they are ready to leave our facility. Our delivery network makes shipping fast and easy! Each project is different and your timeline will be discussed when the order is placed.
Applications & Use Cases

Precast box beams are used in highway and roadway bridges, pedestrian crossings, parking structures, and marine platforms, providing efficient, high-strength solutions for short- to medium-span structures that demand durability and rapid installation.

Our Locations

SAN MARCOS, TEXAS (HEADQUARTERS)

Heldenfels Enterprises, Inc.

5700 IH-35 South. San Marcos, TX 78666

Tel: (512) 396-2376

Fax: (512) 396-2381

CORPUS CHRISTI, TEXAS

Heldenfels Enterprises, Inc.

2222 Laredo St. Corpus Christi, TX 78405

Juan Aguirre: (361) 533-1031

Heldenfels Headquarters

Heldenfels Corpus Christi

Frequently Asked Questions

What are precast box beams used for?

Precast box beams are primarily used in highway and roadway bridges, but they’re also ideal for pedestrian bridges, parking structures, and marine platforms where strength, durability, and efficient installation are critical.

What are the advantages of using box beams over other beam types?

Box beams provide high load capacity with a compact profile, allowing for longer spans and reduced overall structure depth. Their closed shape enhances torsional resistance and durability while simplifying maintenance and drainage.

Can box beams be customized for non-standard applications?

Yes. Our engineering team regularly designs custom box beam geometries, reinforcement layouts, and connection details to meet unique project needs such as pedestrian or marine structures.

Are Heldenfels box beams approved for TxDOT or other state specifications?

Yes. Heldenfels manufactures box beams in full compliance with TxDOT standards and can also produce custom designs for county, municipal, and private projects.

How do box beams perform in harsh environments like coastal or marine settings?

Heldenfels box beams are produced with dense, low-permeability concrete and optimized reinforcement cover, providing excellent resistance to chlorides, moisture intrusion, and freeze-thaw cycles for long-term durability in coastal or industrial applications.

Larry Miller, PE

VP of Pre Construction & Business Development

Speak with a Prestressed Wall Panel Expert Today!

Direct message an experienced Prestressed Wall Panel expert about your project. We are happy to discuss your project’s goals and expectations.